MathemagiciansLibraryExplorationsDeep Dives
← Physics · Upper Secondary
PhysicsUpper Secondary

Uses and dangers of radiation

PU6 — Modern Physics › PU6.2 — Radioactivity and NuclearLecture 4 of 4~2350 words

Radioactive on purpose

A hospital injects a radioactive substance into a patient, on purpose. A few hours later, she lies under a camera that sees the radiation coming out of her body. By the next morning, most of the radioactivity has gone. On the ceiling of many homes, a smoke alarm holds a tiny alpha source that will keep working for centuries.

So is radiation dangerous or useful? That is the wrong question, and it is why so many conversations about radiation go badly. The right questions are more precise. Which radiation? How much? For how long? And is the source outside the body or inside it?

The last lecture ended with a promise: half-life decides which isotopes are useful for dating, medicine and industry, and which are dangerous. This lecture keeps it. Every use, and every danger, comes from two properties you already know: how far the radiation travels, and how fast the source decays. Learn the method, not a list.

Why radiation harms: ionisation inside cells

The lecture on alpha, beta and gamma showed that radiation loses its energy by ionising atoms: knocking electrons out of them. In a living cell, an ionised atom can break a chemical bond. The most important molecule to break is DNA, the molecule that carries the cell's instructions.

Cells repair most DNA damage. But a repair can go wrong. A badly repaired cell may later divide out of control, which is cancer. A very large dose damages so many cells that they die faster than the body can replace them. That causes radiation sickness within days.

So we need to measure "how much". Two quantities are used.

A sievert is a very large dose, so everyday doses are given in millisieverts (mSv).

Background radiation: the dose you cannot avoid

Everyone receives radiation all the time from natural sources. In the UK, the average person receives about 2.7 mSv a year from all sources, and about 84% of that is natural.

Radon gas (from the ground)1.30 mSv (48%)Medical X-rays and scans0.43 mSv (16%)Gamma from ground and buildings0.35 mSv (13%)Cosmic rays from space0.32 mSv (12%)Food and drink0.30 mSv (11%)00.51.01.52.0Dose per year (mSv)
The average UK yearly dose of about 2.7 mSv, split by source (UK government figures). Radon is almost half. Medical uses, in grey-blue, are the only large human-made part.

The largest part is radon, the gas from the alpha lecture, which seeps out of rocks and soil into buildings. About 13% comes from gamma rays from the ground and buildings, 12% from cosmic rays, and 11% from radioactive atoms in food and drink. Almost all the rest is medical. The numbers vary from place to place. In areas with a lot of radon, the dose can be several times the average.

Background radiation gives us a scale. The table puts some doses on it.

Source of doseEffective dose (mSv)Same as natural background for about
Chest X-ray0.0142 days
Flight across the Atlantic0.0811 days
CT scan of the head1.46 months
CT scan of the chest6.62.4 years
Nausea and a fall in white blood cells1000about 370 years

The last column uses the UK average of 2.7 mSv a year. A CT scan is not "about a year of background" in general. A head scan is a few months; a chest scan is a few years. The comparison always depends on the scan.

Outside or inside: irradiation and contamination

There are two different ways to receive a dose, and they need different protection.

This is why the alpha lecture said that danger "depends where the source is". Outside the body, alpha is the least dangerous: the dead outer layer of skin stops it. Inside the body, alpha is the most dangerous: all its energy goes into a few living cells. Radon is dangerous for exactly this reason. It is breathed in, and it and its decay products give out alpha particles inside the lungs.

Against irradiation, three simple tools work: time (a shorter exposure means a smaller dose), distance and shielding. For gamma rays from a small source, the dose rate falls with the square of the distance. Twice as far away gives a quarter of the dose rate. Alpha and beta simply stop after a short range, so distance protects even more strongly against them.

Stop and think

Spices and medical syringes are often sterilised by strong gamma rays from cobalt-60. Does this make them radioactive?

Show the answer

No. They are irradiated, not contaminated. The gamma rays pass through, ionise molecules in any bacteria, and are gone. No radioactive atoms are added. A gamma photon of about 1 MeV does not have enough energy to make the nuclei of the spices radioactive.

This is the advantage of the method. The packs can be sealed first and sterilised afterwards, without heat, and they are safe to handle at once.

Choosing an isotope: two questions

Every use of radioactivity answers the same two questions.

Choosing a radioactive isotope

1. Choose the radiation by what it must pass through, and what must stop it.

2. Choose the half-life by how long the job lasts, and how long the source may stay.

Try the first question yourself. Sort each job by the radiation it needs.

Sort — which radiation does the job?

Put each job in the box for the radiation it needs. Read the reason after each card.

Eight jobs, sorted by the radiation each needs.

  • Alpha. Ionising the air in a small gap inside a smoke alarm. The radiation from radon that harms the lungs.
  • Beta. Checking the thickness of paper on a production line. Checking the thickness of thin aluminium foil.
  • Gamma. A tracer that must be seen by a camera outside the body. Sterilising sealed packs of syringes. Finding a leak in a pipe buried under the ground. Measuring the liquid level inside a closed steel tank.

Now the second question. A medical tracer is the clearest case, because both choices matter at once. The doctor needs gamma rays to leave the body, and needs the source to last through the scan but not for weeks afterwards. Try the choices below.

Model — design a medical tracer

The tracer reaches the organ about 1 hour after injection, and the scan takes place then. Choose the radiation and the half-life. Watch what is left at the scan, after one day and after one week.

Radiation:

Half-life:

The percentage of a tracer left at the scan (1 hour), after 1 day and after 1 week, for four half-lives. Only a gamma emitter can be seen from outside the body.

Half-lifeLeft at 1 hourLeft at 1 dayLeft at 1 weekVerdict
6 minutes≈ 0.1%≈ 0%≈ 0%gone before the scan
6 hours≈ 89.1%≈ 6.3%≈ 0%good: strong at the scan, gone in a few days
6 days≈ 99.5%≈ 89.1%≈ 44.5%strong, but keeps giving a dose for weeks
6 years≈ 100%≈ 100%≈ 99.8%stays for years

That is it. That is the whole idea. Gamma, because the camera is outside. Six hours, because the scan is a few hours long and the patient goes home. The real choice, technetium-99m, has a half-life of about 6.0 hours and gives out gamma rays of about 140 keV. It is used in tens of millions of scans each year, more than any other medical isotope.

The model leaves two things out. The body also removes some of the tracer, for example in urine, which lowers the dose further. And the tracer must be attached to a chemical that carries it to the right organ. That is chemistry, not physics, but it decides what the scan can show.

The other uses, by the same two questions

Radiocarbon dating: half-life as a clock

Cosmic rays turn some nitrogen in the air into carbon-14, which is radioactive (beta, half-life about 5730 years). Plants take it in with carbon dioxide, and animals eat the plants. So every living thing contains a small, steady share of carbon-14.

When the organism dies, it stops taking in carbon. From then on, its carbon-14 decays and is not replaced. Measure how much is left, compared with living material, and you know how many half-lives have passed.

5730 years, 50%11 460 years, 25%about 0.2%left at 50 000 y020 00040 00060 0000255075100Time since death (years)Carbon-14 left (%)
Carbon-14 left in dead material. It halves every 5730 years. After about 50 000 years only about 0.2% is left, too little to measure reliably.

The method has limits at both ends. For things only a few hundred years old, too little has decayed to measure the difference well. Beyond about 50 000 years, too little is left. There is also a correction. The amount of carbon-14 in the air has not been constant over time, and nuclear weapons tests in the 1950s and early 1960s raised it sharply. So laboratories convert a measured "radiocarbon age" into a calendar date using a calibration curve, built from tree rings and other samples of known age. The current curve is called IntCal20.

Worked examples

Worked Example 1 — A tracer after one day

A dose of technetium-99m has an activity of 4.0 × 10⁸ Bq when it is injected. The half-life is 6.0 hours. How long until the activity falls to 2.5 × 10⁷ Bq?

Fraction left. 2.5 × 10⁷ ÷ 4.0 × 10⁸ = 0.0625 = 1/16.

Half-lives. 1/16 = (½)⁴, so 4 half-lives have passed.

Time. 4 × 6.0 = 24 hours.

Check. 4.0 × 10⁸ → 2.0 × 10⁸ → 1.0 × 10⁸ → 5.0 × 10⁷ → 2.5 × 10⁷: four halvings ✓. After one day, 6.25% is left, as in the model.

Worked Example 2 — Dating a bone

A bone from an archaeological site has a carbon-14 activity per gram of carbon that is 25% of the activity in living material. How old is it?

Half-lives. 25% = ¼ = (½)², so 2 half-lives.

Age. 2 × 5730 = 11 460 years.

Honest answer. This is the radiocarbon age. A laboratory would then use the calibration curve to turn it into a calendar date, which can differ by hundreds of years.

Worked Example 3 — Why a smoke alarm never needs a new source

A smoke alarm contains americium-241 with an activity of 37 kBq. The half-life is 432.6 years. What is the activity after 10 years?

Number of half-lives. n = 10 ÷ 432.6 ≈ 0.0231.

Fraction left. (½)0.0231 ≈ 0.984.

Activity. 37 × 0.984 ≈ 36.4 kBq.

Meaning. After 10 years the source has lost less than 2% of its activity. The alarm is replaced because its electronics age, not because the source runs out. Here a long half-life is exactly what the job needs.

Worked Example 4 — Time, distance and shielding together

A worker near a small cobalt-60 source receives 80 μSv per hour at 2 m. He moves to 4 m, works for 30 minutes instead of an hour, and stands behind 2.4 cm of lead. (For cobalt-60 gamma rays, each 1.2 cm of lead halves the dose rate.) What dose does he receive?

Distance. Twice as far: (½)² = ¼. 80 ÷ 4 = 20 μSv per hour.

Shielding. 2.4 cm is two halving thicknesses: 20 ÷ 4 = 5 μSv per hour.

Time. Half an hour: 5 × 0.5 = 2.5 μSv.

Check. The three tools together cut the dose from 80 μSv to 2.5 μSv, a factor of 32 = 4 × 4 × 2 ✓. That is about 0.1% of the UK yearly average of 2700 μSv.

Trap 1 — "Irradiated means radioactive"

Food or equipment exposed to gamma rays is irradiated, not contaminated. It does not become radioactive. Contamination means radioactive atoms have been added, on or in something.

Trap 2 — "Gamma is always the most dangerous"

Outside the body, gamma is the hardest to stop. Inside the body, alpha does the most damage, because all its energy goes into a few cells. Always say where the source is.

Trap 3 — "A short half-life is always safer"

For the same number of nuclei, a shorter half-life means a higher activity: the same decays happen in less time. A short half-life is safer only because the source disappears sooner. A long half-life gives a lower activity that lasts longer.

Try it yourself

Work each one on paper first. Open a hint only when you are stuck.

  1. Engineers want to find a leak in a water pipe buried 1 m under a road. They plan to add a radioactive isotope to the water and walk along the road with a detector. Choose the type of radiation and a suitable half-life, giving a reason for each.

    Hint 1

    What must the radiation pass through to reach the detector?

    Hint 2

    The search takes hours. What happens to the water supply afterwards?

    Full answer

    Gamma, because the radiation must pass up through 1 m of soil and road to reach the detector. Alpha and beta would be stopped.

    A half-life of a few hours to a day or so. It must last long enough to flow through the pipe and be searched for. But the isotope ends up in the soil and the water supply, so it should decay away soon after.

    Check: both choices follow the two questions, what it must pass through and how long the job lasts ✓.

  2. (a) Wood from an ancient boat has 12.5% of the carbon-14 activity of living wood. Find its radiocarbon age. (b) A sample has 0.05% of the activity of living material. Why can it not be dated reliably?

    Hint 1

    12.5% is one eighth. How many halvings is that?

    Hint 2

    For (b), compare 0.05% with the amount left after 10 half-lives.

    Full answer

    (a) 1/8 = (½)³, so 3 half-lives: 3 × 5730 = 17 190 years (then calibrated).

    (b) After 10 half-lives (about 57 000 years), only (½)¹⁰ ≈ 0.1% is left. 0.05% is less than that, about 11 half-lives. So little carbon-14 is left that the count is hard to separate from the background and from tiny traces of modern carbon. The sample is beyond the method's limit.

    Check: (½)³ = 0.125 ✓ and (½)¹¹ ≈ 0.049% ✓.

  3. Iodine-131 gives out both beta particles and gamma rays, and has a half-life of about 8 days. The thyroid gland collects iodine. Doctors use a large dose of iodine-131 to treat an overactive thyroid. (a) Which radiation does the treatment, and which lets doctors check where the iodine went? (b) What fraction of the activity is left after 24 days? (c) Why are patients asked to keep their distance from small children for a few days?

    Hint 1

    Which radiation deposits its energy within a few millimetres, inside the gland?

    Hint 2

    24 days is how many half-lives?

    Full answer

    (a) The beta particles do the treatment: they travel only a few millimetres, so their energy goes into the thyroid itself. The gamma rays leave the body, so a camera can show where the iodine collected.

    (b) 24 ÷ 8 = 3 half-lives, so (½)³ = 1/8 of the activity is left.

    (c) The gamma rays leave the patient's body, so people nearby are irradiated. Children are more sensitive to radiation. Distance and time cut their dose, and after a few half-lives the activity is much lower.

    Check: (½)³ = 0.125, one eighth ✓.

  4. Two sources each contain 1.0 × 10²⁰ nuclei. Source P has a half-life of 6.0 hours. Source Q has a half-life of 6.0 years. (a) Using A = λN with λ = 0.693 ÷ T½, find each activity in becquerels. (b) Which is more dangerous to stand next to today, and which is more of a problem as waste? Explain.

    Hint 1

    Convert both half-lives to seconds first: 6.0 h = 21 600 s, 6.0 years ≈ 1.89 × 10⁸ s.

    Hint 2

    λ for P = 0.693 ÷ 21 600 per second.

    Full answer

    (a) P: λ = 0.693 ÷ 21 600 ≈ 3.21 × 10⁻⁵ s⁻¹, so A ≈ 3.21 × 10⁻⁵ × 1.0 × 10²⁰ ≈ 3.2 × 10¹⁵ Bq.

    Q: λ = 0.693 ÷ 1.89 × 10⁸ ≈ 3.66 × 10⁻⁹ s⁻¹, so A ≈ 3.7 × 10¹¹ Bq.

    (b) Today, P is far more dangerous: its activity is about 8800 times larger. But P is almost gone in a few days, while Q keeps its activity for years. So Q is more of a problem as waste. A short half-life means intense and brief; a long one means weak and lasting.

    Check: the ratio of activities equals the ratio of half-lives, 6 years ÷ 6 hours ≈ 8770 ✓.

The bigger idea

Radiation protection rests on a simple rule: every extra dose must bring a benefit larger than its risk, and must be kept as low as reasonably achievable. A chest CT scan of 6.6 mSv equals a few years of background radiation. For someone who needs it, the information is worth far more than the small added risk. For someone who does not, it is a dose for nothing. Physics cannot make that decision, but it lets you make it with numbers instead of fear.

This lecture also completes radioactivity at this level. The same ideas carry forward. At Pre-University, the energy inside the nucleus explains why heavy nuclei split in fission and light ones join in fusion, and decay series follow a nucleus through many steps.

Key concepts in this lesson